Factory Defaulting the system
- Keypad plug into the panel using engineer lead
- Press & hold the reset button then power up
- 1234 engineer default code
Setting up the Panel
- Commissioning Jumper ON
- Plug the keypad engineer lead into panel (red black,yellow,blue)
- EXP 1 should show when the commission Jumper ON
- Learn the devices
- To learn the keypad YES or ticked in the Learn Device then remove the eng lead
- Yes to learn the keypad
- Confirm the Keypad engineer code 1234 then go to engineer utils confirm devices
- Tick RKP>1 and EXP>1
Smart Com Setup
- Engineer code then Option 7 – UDL/Digi Options – Press YES
- Option – 8 Com Port Setup – Press YES
- Press YES – Onboard Digicom – Nothing Fitted
- Press NO – Com Port 1 Nothing Fitted
- Scroll up then select SmartCom – Press YES
- Press YES – Com Port 1 SmartCom
- Press NO – Com Port 2 Nothing Fitted
- Press 4 – to select ComIP Module – Press YES
- Press Menu – Com Port Setup
- then Menu again
Setup UDL Password
- Option 7 – UDL/Digi Option then YES
- Option 5 – UDL Options then YES
- Option 4 – UDL Password – Press NO to edit
- Enter UDL password 4321 then YES
- Press YES – then Press Menu
Configure the Panel for Texecom Connect
- Option 7 – UDL/Digi Options then YES
- Option 3 – Program Digi – YES
- Press NO – ARC 1 Protocol Disabled
- Press 7 – to select Texecom Connect then YES
- Press Menu
Enabling the Texecom Connect App
- Option 7 – UDL/Digi Options then YES
- Option 4 – Enable Texecom Connect App then YES
- The system should generate the App Code: xxxxxx